![background image](http://html1.mh-extra.com/html/omron/ej1-07-2008/ej1-07-2008_operation-manual_743567192.webp)
173
List of Connectable Devices
Appendix C
Crimp Terminals for DeviceNet Communications Cables
Terminating Resistors for DeviceNet Network
A Terminating Resistor can also be connected to a T-branch Tap or a one-branch Power Supply Tap.
T-branch Taps
One-branch Taps
Three-branch Taps
Model Crimper
Remarks
Manufacturer
AI series:
AI-0.5-8WH-B for Thin Cable
(product code: 3201369)
ZA3
For single-wire insertion
PHOENIX CONTACT
AI series:
AI-TWIN2×0.5-8WH for Thin Cable
(product code: 3200933)
UD6
(product code: 1204436)
For two-wire insertion
(multi-drop wiring)
Model
Specifications
Manufacturer
DRS1-T
Terminal-block Terminating Resistor, 121
Ω
±
1% 1/4 W
OMRON
DRS2-1
Shielded Terminating Resistor (male plug), micro-size (M12)
DRS2-2
Shielded Terminating Resistor (female socket), micro-size (M12)
DRS3-1
Shielded Terminating Resistor (male plug), mini-size
Model
Specifications
Manufacturer
DCN1-1C
Includes three XW4B-05C1-H1-D parallel connectors with screws
(When used on a trunk line, one branch line can be connected.)
Connector insertion direction: Horizontal
A Terminating Resistor (included as standard) can be connected.
OMRON
DCN1-2C
Includes three XW4B-05C1-H1-D parallel connectors with screws
(When used on a trunk line, one branch line can be connected.)
Connector insertion direction: Vertical
A Terminating Resistor (included as standard) can be connected.
OMRON
DCN1-2R
Includes three XW4B-05C1-VIR-D orthogonal connectors with screws
(When used on a trunk line, one branch line can be connected.)
Connector insertion direction: Vertical
A Terminating Resistor (included as standard) can be connected.
OMRON
Model
Specifications
Manufacturer
DCN1-3C
Includes five XW4B-05C1-H1-D parallel connectors with screws
(When used on a trunk line, three branch lines can be connected.)
Connector insertion direction: Horizontal
A Terminating Resistor (included as standard) can be connected.
OMRON
DCN1-4C
Includes five XW4B-05C1-H1-D parallel connectors with screws
(When used on a trunk line, three branch lines can be connected.)
Connector insertion direction: Vertical
A Terminating Resistor (included as standard) can be connected.
OMRON
DCN1-4R
Includes five XW4B-05C1-H1-D orthogonal connectors with screws
(When used on a trunk line, three branch lines can be connected.)
Connector insertion direction: Vertical
A Terminating Resistor (included as standard) can be connected.
OMRON
Summary of Contents for EJ1 - 07-2008
Page 3: ...iv...
Page 19: ...xx...
Page 33: ...14 Initial Temperature Controller Settings Section 1 4...
Page 53: ...34 Wiring the Temperature Controllers Section 3 4...
Page 101: ...82 Ladder Programming Examples Section 4 6...
Page 143: ...124 Sending Explicit Messages Section 6 5...
Page 155: ...136 Message Communications Characteristics Section 7 2...
Page 163: ...144 Maintenance Section 8 2...
Page 189: ...170 Allocation Numbers for Configurators Manufactured by Other Companies Appendix B...
Page 197: ...178 Index...