80
Extended Data 2 I/O Mapping
APPENDIX C
Note
The Torque Compensation only becomes effective if: P036 = 5,
A044 = 3 and ATR is assigned to a digital input and turned on. Re-
fer to MX2 User Manual section 3-9-4.
Note
The Analog Output Channel 1 only becomes effective if: C028 =
16. Refer to MX2 User Manual section 3-7.
Note
A Digital Output only becomes effective if the associated register
(C021, C022 or C026) is set to 63. Refer to MX2 User Manual sec-
tion 3-7.
Note
The Torque Reference only becomes effective if: P033 = 7. Refer
to RX User Manual section 4-3 Torque Control for details.
Note
The Torque Compensation only becomes effective if: P036 = 5.
Refer to RX User manual 4-3 Torque Bias.
Note
The Analog Output Channel 1 only becomes effective if: C028 =
20. Refer to RX User Manual section 4-2 Analogue Output AM/
AMI Terminals.
Note
A Digital Output only becomes effective if the associated register
(C021- C026) is set to 63. Refer to RX User Manual section 4-2
Multi-function Output Terminal Selection.
C-3
Extended Data 2 I/O Mapping
C-4
Operation Command and Inverter Status Registers
Table C-3 Ext2 data format I/O mapping
Word Offset
Output Area
Input Area
+0
Operation Command
*1
(Section C-4)
*1.
Refer to
section C-4 Operation Command and Inverter Status Registers
on page 80 for the Op-
eration Command and Inverter Status register definitions
Inverter Status
*1
(Section C-4)
+1
Frequency Reference
Output Frequency
+2
Modbus
Message Area
(Section C-5)
Instruction
Modbus
Message Area
(Section C-5)
Result
+3
+4
Data
Data
+5
Control
Status
Table C-4 Conventional control status regs
Bit
Operation Command
Inverter Status
Name
Description
Name
Description
0
Forward Run/Stop (FW) 1: Run forward
0: Stop run forward
Operation Status
1: Inverter is running
0: Inverter is stopped
1
Reverse Run/Stop (RV)
1: Run reverse
0: Stop run reverse
0 Hz Detection
Signal (ZS)
1: ON
0: OFF
2
Intelligent Input
Terminal override [3]
1: ON
0: OFF
Rotation Direction
1: Reverse rotation
0: Forward rotation
3
Intelligent Input
Terminal override [4]
1: ON
0: OFF
Trip Reset Status
1: Trip reset (RS) is active
0: Trip reset (RS) not active
4
Intelligent Input
Terminal override [5]
1: ON
0: OFF
Set Frequency Reached
(FA3)
1: ON
0: OFF
5
Intelligent Input
Terminal override [6]
1: ON
0: OFF
Inverter Ready
1: ON
0: OFF
6
Intelligent Input
Terminal override [7]
1: ON
0: OFF
Alarm Signal (AL)
1: ON
0: OFF
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 80 Donnerstag, 8. September 2011 11:53 11
Summary of Contents for 3G3AX-MX2-PRT-E
Page 6: ...vi...
Page 14: ...xiv Compliance with EC Directives...
Page 20: ...6 Introduction to PROFIBUS Section 1 3...
Page 36: ...22 How to mount the Option Board on the Inverter Section 2 3...
Page 42: ...28 Configuring the Network Section 3 2...
Page 70: ...56 Limitations Caused by Inverter Mode and Rating Selection Section 4 7...
Page 108: ...94 APPENDIX G...
Page 110: ...96 APPENDIX H...
Page 113: ...97...
Page 115: ......