![background image](http://html1.mh-extra.com/html/omron/3g3ax-mx2-prt-e/3g3ax-mx2-prt-e_user-manual_742058033.webp)
19
How to mount the Option Board on the Inverter
Section 2-3
Step 11
If the
desired parameters of the Inver-
ter have been set succesfully
, discon-
nect the 3G3AX CAJOP300-EE cable
or straight EtherNet cable from the
Inverter.
Push the blind cover (no.1) into place.
Note
Refer to section 2 in the RX User's Manual (Cat. No. I560) for operations
related to assembly and disassembly of the RX Inverter.
2-3-3
Installation Environment Clearance
Please adhere to the requirements of the Inverter for Installation Environment
clearance.
Please refer to the MX2 Inverter manual
(Cat. No. I570)
section 2-3-2.
Please refer to the RX Inverter manual (Cat. No. I560) section 2-1 Installation
Environment.
In addition to this, provide sufficient clearance to allow connection and
removal of the PROFIBUS Connector. No unnecessary strain should be
placed on the PROFIBUS cable or connector that could be transferred to the
Option Board.
2-3-4
PROFIBUS network connector
The PROFIBUS connector on the bottom of the Unit is a 9-pin female sub-D
connector, as recommended by IEC 61158. Fixtures have #4/40 UNC thread
for compatibility with PROFIBUS-DP connectors. No termination is provided
inside the Option Board.
The signals DGND and VP are used to power the bus terminator located in
the cable connector.
Note 1
The Option Board allows the use of PROFIBUS connectors with a straight
cable outlet.
1
Table 4 PROFIBUS connector pinout
Pin No. Signal
Description
1
Shield Functional ground (do not connect)
2
NC
-
3
B-line
Data signal
4
RTS
Control signal for repeaters
(direction control)
5
DGND Signal ground
6
VP
Termination power
7
NC
-
8
A-line
Data signal
9
NC
-
9
5
1
6
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 19 Donnerstag, 8. September 2011 11:53 11
Summary of Contents for 3G3AX-MX2-PRT-E
Page 6: ...vi...
Page 14: ...xiv Compliance with EC Directives...
Page 20: ...6 Introduction to PROFIBUS Section 1 3...
Page 36: ...22 How to mount the Option Board on the Inverter Section 2 3...
Page 42: ...28 Configuring the Network Section 3 2...
Page 70: ...56 Limitations Caused by Inverter Mode and Rating Selection Section 4 7...
Page 108: ...94 APPENDIX G...
Page 110: ...96 APPENDIX H...
Page 113: ...97...
Page 115: ......