86
Read Parameter Request
APPENDIX E
E-1
Read Parameter Request
Note 1
The request header is preceded by the DP and MSAC2 headers. Describing
these however is outside the scope of this manual.
Note 2
Please refer to
APPENDIX F Option Board Parameters
on page 91
Table E-1 PROFIdrive V4 Parameter read request
Word Offset
Contents
High byte
Low byte
+0
Request Header
*1
REF
RT
+1
DO
N
+2
1
st
Parameter Address
PA
1
CA
1
+3
PNU
1
+4
IND
1
+ (LEN-3)
N
th
Parameter Address
PA
N
CA
N
+ (LEN-2)
PNU
N
+ (LEN-1)
IND
N
REF
Request reference (Typically incremented by user program)
RT
Request type:
01h
: Parameter read instruction
DO
Drive object:
01h
: Inverter number (Only one attached to Option Board)
N
The number of parameter addresses to follow
PAx
Parameter attribute:
10h
: Read value(s)
CAx
The number of elements:
0
: Single value read (Non array)
1..255
: Number of elements to read
PNUx
Parameter number:
0..889
: Reserved
4001..4999
: Parameters d001 to d999
890-999
: Option Board parameters
*2
6001..6999
: Parameters F001 to F999
1001..1999
: Parameters A001 to A999
8001..8999
: Parameters H001 to H999
2001..2999
: Parameters b001 to b999
16001..16999
: Parameters P001 to P999
3001..3999
: Parameters C001 to C999
21001..21999
: Parameters U001 to U999
INDx
Index to start reading from:
0
: Single value read (Non array)
1..65535
: Specified array index
LEN
Parameter request frame size in words
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 86 Donnerstag, 8. September 2011 11:53 11
Summary of Contents for 3G3AX-MX2-PRT-E
Page 6: ...vi...
Page 14: ...xiv Compliance with EC Directives...
Page 20: ...6 Introduction to PROFIBUS Section 1 3...
Page 36: ...22 How to mount the Option Board on the Inverter Section 2 3...
Page 42: ...28 Configuring the Network Section 3 2...
Page 70: ...56 Limitations Caused by Inverter Mode and Rating Selection Section 4 7...
Page 108: ...94 APPENDIX G...
Page 110: ...96 APPENDIX H...
Page 113: ...97...
Page 115: ......