17
How to mount the Option Board on the Inverter
Section 2-3
Step 6
Press down carefully the two locking
pins (no. 1) of the Option Board.
Press carefully the top of the Option
Board in the Inverter.
Check the Option Board is being
locked by the locking pins (no.1).
Step 7
Insert the screw (no. 1) into the upper
right hole in the Option Board (no.2).
Tighten the screw into place (do not
over tighten).
Fix the Option Board grounding cable
to the chassis ground of the RX-
Inverter under an already fixed chas-
sis grounding bold.
See the bold with the grounding fig-
ure.
The position of the chassis ground
vary from inverter type. Illustrations
are only provided for one Inverter
size. The instructions however are
generic and may be followed for all
Inverter sizes.
1
2
G
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 17 Donnerstag, 8. September 2011 11:53 11