75
APPENDIX B
APPENDIX B
Parameter Process Data Object Modules
The Parameter Process Data Object (PPO) modules implement the cyclic
data exchange mapping for the PROFIdrive device profile. Five modules are
supported (PPO1 - PPO5) allowing you to select the number of exchanged
registers and PKW messaging support. All modules provide two default out-
put words: STW (Control word) and HSW (Frequency Reference), provide
control over the Inverter. All modules additionally provide two default input
words: ZSW (Status Word) and HIW (Output Frequency) provide feedback on
the Inverter status. STW and ZSW are explained in more detail in
appendix B-
2
. HSW and HIW are explained in
appendix B-3
. The exchanged Modbus reg-
isters are configured by setting Inverter registers P160 - P179 to the appropri-
ate Inverter Modbus addresses. If P160, P161, P170 or P171 are set to 0,
STW, HSW, ZSW and HIW are used.
Note
Set P182 = 0 for the Option Board to support the PPO modules
Note
The Inverter places some restrictions on the Modbus register selection. For a
Modbus Register to be mapped for output data exchange, it must be a run-
mode edit register that provides write-access. Double-word Modbus registers
must be mapped in sequence: high-word following low-word. It is not allowed
to map the same register more than once in the output area.
Tip
Refer to section B-4-2 of the MX2 Inverter user’s manual for a list
of the Inverter registers that provide write access.
Tip
Refer to section 5 of the RX2 Inverter user’s manual for a list of the
Inverter registers that provide write access.
Tip
Refer to section 3-2-3 of the MX2 Inverter user’s manual for an
explanation on run-mode edit registers. Also note that the run-mode
edit requirement can be disabled with b031.
Tip
Refer to section 5 of the RX Inverter user’s manual for an explana-
tion on run-mode edit registers. Also note that the run-mode edit
requirement can be disabled with b031.
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 75 Donnerstag, 8. September 2011 11:53 11
Summary of Contents for 3G3AX-MX2-PRT-E
Page 6: ...vi...
Page 14: ...xiv Compliance with EC Directives...
Page 20: ...6 Introduction to PROFIBUS Section 1 3...
Page 36: ...22 How to mount the Option Board on the Inverter Section 2 3...
Page 42: ...28 Configuring the Network Section 3 2...
Page 70: ...56 Limitations Caused by Inverter Mode and Rating Selection Section 4 7...
Page 108: ...94 APPENDIX G...
Page 110: ...96 APPENDIX H...
Page 113: ...97...
Page 115: ......