20
How to mount the Option Board on the Inverter
Section 2-3
Note 2
The 9-pin sub-D connector uses #4/40 UNC thread for mechanical fixation of
the cable connector. Always use PROFIBUS connectors.
!Caution
Do not use PROFIBUS connectors with a 90° cable outlet (Such connectors
place unnecessary strain on the Option Board connector).
2-3-5
Option Board Dimensions
c
d2
w
h1
h
d4
d3
d
d1
Table 5 Option Board Dimensions
Item
Dimension
Item
Dimension
Item
Dimension
h
63.6 mm
c
16.3 mm
d2
31.3 mm
h1
57.9 mm
d
52.6 mm
d3
44.8 mm
w
67.6 mm
d1
1
1. Dimension d1 gives the increase in MX2
@
Inverter dimension D when the Option Board is
fitted (Refer to section 2-3 of the Inverter user's manual).
26.4 mm
d4
28.4 mm
3G3AX-PRT-MX2
RUN ERR BF COMM
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 20 Donnerstag, 8. September 2011 11:53 11