25
Configuring the Option Board
Section 3-1
Apply the source selection parameters according the following table for the
RX Option Board.
Step 6
The PPO modules and Flexible module give you the freedom to select/cus-
tomise the Inverter Modbus registers for Cyclic Data Exchange. Inverter regis-
ters P160 - P179 are used to configure and map the exchanged Modbus
registers. If required, adjust these registers to change the default content of
the exchanged data. Please refer to Appendices
B-1 I/O Mapping
on page 76
and
Flexible I/O Mapping
on page 83 for more details.
Param
Description
Setting
P033
Torque Command
Source
For Option Board as source:
Set to 7 (Use Option Board register) if P182
equals 1
Set to 3 (Use P034) if P182 equals 0 or 2
P036
Torque Bias Mode
For Option Board as source:
Set to 6 (Bias set by Option Board) if P182
equals 1
Set to 0 (Bias according to sign) or 1 (Bias accord-
ing to rotation direction) if P182 equals 0 or 2
C021
Output Terminal 11
Source
Set to 63 for Option Board as source
C022
Output Terminal 12
Source
Set to 63 for Option Board as source
C026
Alarm Relay Output
Terminal Source
Set to 63 for Option Board as source (Optional)
C028
Analog Output AM
Source
Set to 20 for Option Board as source
Table 12 Configuration of input and output content
Param
Description
Setting
P160
Output Register 1
contents
Modbus register mapped into PZD1 or flexible out-
put word 1
P161
Output Register 2
contents
Modbus register mapped into PZD2 or flexible out-
put word 2
P162
Output Register 3
contents
Modbus register mapped into PZD3 or flexible out-
put word 3
P163
Output Register 4
contents
Modbus register mapped into PZD4 or flexible out-
put word 4
P164
Output Register 5
contents
Modbus register mapped into PZD5 or flexible out-
put word 5
P165
Output Register 6
contents
Modbus register mapped into PZD6 or flexible out-
put word 6
P166
Output Register 7
contents
Modbus register mapped into PZD7 or flexible out-
put word 7
P167
Output Register 8
contents
Modbus register mapped into PZD8 or flexible out-
put word 8
P168
Output Register 9
contents
Modbus register mapped into PZD9 or flexible out-
put word 9
P169
Output Register 10
contents
Modbus register mapped into PZD10 or flexible
output word 10
P170
Input Register 1 con-
tents
Modbus register mapped into PZD1 or flexible
input word 1
P171
Input Register 2 con-
tents
Modbus register mapped into PZD2 or flexible
input word 2
P172
Input Register 3 con-
tents
Modbus register mapped into PZD3 or flexible
input word 3
P173
Input Register 4 con-
tents
Modbus register mapped into PZD4 or flexible
input word 4
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 25 Donnerstag, 8. September 2011 11:53 11
Summary of Contents for 3G3AX-MX2-PRT-E
Page 6: ...vi...
Page 14: ...xiv Compliance with EC Directives...
Page 20: ...6 Introduction to PROFIBUS Section 1 3...
Page 36: ...22 How to mount the Option Board on the Inverter Section 2 3...
Page 42: ...28 Configuring the Network Section 3 2...
Page 70: ...56 Limitations Caused by Inverter Mode and Rating Selection Section 4 7...
Page 108: ...94 APPENDIX G...
Page 110: ...96 APPENDIX H...
Page 113: ...97...
Page 115: ......