60
Troubleshooting using the LED indicators
Section 5-1
5-1-4
PROFIBUS Errors
If the PROFIBUS master is correctly configured and there are no wiring
errors, the COMM indicator will be ON and the BF indicator OFF. The table
below shows the indicator patterns caused by configuration PROFIBUS
errors.
Table 81 PROFIBUS Errors
MX2
Display &
Indicators
RX
Display &
Indicators
Possible Cause(s)
Corrective Action
The PROFIBUS master cannot communi-
cate with the Option Board because the
PROFIBUS configuration is not correct.
Check (and correct) the following items:
• Does the node address in your PROFI-
BUS master configuration program match
P180?
• Does any other slave device on the PRO-
FIBUS network also have the same node
address?
• Is the PROFIBUS master ON-LINE?
• If you are using OMRON CX-Configurator:
Make sure that the 'Enable DPV1 option'
on the 'DPV1' tab is NOT checked.
The PROFIBUS wiring is not correct.
Check (and correct) the following items:
• Are the correct pins wired on the PROFI-
BUS connector?
• Are there any short circuits or line interrup-
tions?
• Are you using the correct cable type?
• If you have branches from the PROFIBUS
cable main line: Are any of these branches
too long?
The PROFIBUS network has not been
terminated correctly.
Follow the instruction provided in the PROFI-
BUS Installation Guideline for Cabling and
Assembly to correctly terminate the network.
The Option Board detected too many
communication errors.
Check (and correct) the following items:
• Is the ground cable of the Option Board
connected to a ground terminal on the
Inverter?
Are the MX2 installation guide-
lines to comply with EMC recom-
mendations properly
implemented (refer to MX2 User's
manual section D-1)?
Are the RX installation guidelines
to comply with EMC recommen-
dations properly implemented
(refer to RX User's manual sec-
tion “2-1 Installation”)?)
• Are there any excessive EMI sources near
any of the cables or equipment?
I111E-EN-02+3G3AX-MX2-RX-PRT+OperManual.book Seite 60 Donnerstag, 8. September 2011 11:53 11
Summary of Contents for 3G3AX-MX2-PRT-E
Page 6: ...vi...
Page 14: ...xiv Compliance with EC Directives...
Page 20: ...6 Introduction to PROFIBUS Section 1 3...
Page 36: ...22 How to mount the Option Board on the Inverter Section 2 3...
Page 42: ...28 Configuring the Network Section 3 2...
Page 70: ...56 Limitations Caused by Inverter Mode and Rating Selection Section 4 7...
Page 108: ...94 APPENDIX G...
Page 110: ...96 APPENDIX H...
Page 113: ...97...
Page 115: ......