53
Extended Speed and Acceleration Control IO (110/111)
APPENDIX B
Drive Status
Drive Status
1: Startup
2: Not ready
3: Ready
4: Enabled
5: Stopping
6: Fault / trip stop
7: Faulted / tripped
Rotational
Speed Monitor
Actual rotational speed monitor. Unit: [RPM]/[0.1 Hz]/[0.01 Hz].
If Motor poles setting for RPM (inverter parameter P049 is set to
zero, the Unit depends on the inverter mode (d060):
d060 = 2 (High Frequency mode): Unit is [0.1 Hz]
d060 != 2 (High Frequency mode): Unit is [0.01 Hz]
Output current
monitor
Output current monitor. Unit: [0.1 A]
Trip Cause
Returns direct trip cause. Value 1 to 99 decimal correspond to trip
E01 to E99.
Table B-27 Extended Speed and Acceleration Control Input - Assembly 111
Description (continued)
Name
Description