37
Other Error Causes and Error Procedures
Section 5-2
5-2
Other Error Causes and Error Procedures
This section explains about errors which are not shown as specific LED
indicator states.
Table 27 Other errors
Error event
Possible cause and procedure
Within CX-Integrator, the download or
upload of the parameters of the Unit fail.
The Inverter may have limited write access to the parameters
based on the Inverter mode selected.
The Inverter may be in Trip state, which prevents parameters to
be downloaded.
Check the proper Inverter mode and state before attempting
downloading again.
Explicit message access of the
parameters (using Function Code object
or Modbus Register object) fail.
The Inverter may have limited write access to the parameters
based on the Inverter mode selected.
The Inverter may be in Trip state, which prevents parameters to
be downloaded.
Check the proper Inverter mode and state before attempting
downloading again.