and the message displayed is NOZZLES DAMAGED, this means that there is an electrical
problem. If this happens, consult the table below:
If instead the numbered scale appears as in the figure below:
3. Remove the print head and
clean the electrical contacts
using a dry swab of cotton wool
without touching the printing
nib.
2. Lift the operator console and
open the print head
compartment cover.
4. Clean the electrical contacts
on the print carriage with a
soft, dry cloth.
CAUSE
ACTION
The print head has been replaced or
reinserted incorrectly.
Remove and reinsert the print head and then
carry out the "Automatic Nozzle Cleaning and
Testing Procedure".
There is one or more false contacts.
Carry out the "Cleaning the Electrical Contacts
of the Print Head" procedure and then carry out
the "Automatic Nozzle Cleaning and Testing
Procedure".
One or more contacts are broken.
Replace the print head.
ELECTRICAL
CONTACTS
5. Having reinserted the print head previously removed, close the print head compartment
cover, lower the operator console andturn on the facsimile.
Cleaning the Electrical Contacts on the Print Head
1. Turn off the facsimile.