Troubleshooting
Symptom
Diagnosis / possible cause
No machine reaction after switching on;
no voltage available.
(no fans are running, display and LEDs
are dark)
After switching the power supply on, only the 5.2 V logic voltage is
switched on.
Check if cable A6802 is plugged completely to the 10pin con-
nectors at the power supply and on the CPU board. The cable
plug engages clearly audible to the connector.
Check the logic supply voltage (LED next to the 10pin connec-
tor at the power supply).
– LED off: The power supply output is overloaded (shorted) or the
power supply is defective.
Disconnect cable A6802 from the 10pin connector and switch
the power supply on again.
– LED on: logic voltage (5.2 V) available and stable.
Settings in the function menu are not
stored after switching off.
The power fail signal doesn´t arrive at the CPU; when switching the
machine off, „Power fail - saving done“ is
not
displayed.
Check cable A6802 and replace, if damaged.
Power fail output doesn´t work correctly.
Replace power supply.
Power fail input at the CPU board doesn´t work correctly.
Replace CPU board.
24 V and 17/75 V output voltages are
switched off approx. 10 s after switching
on.
Rotation speed of the power supply fan is being controlled.
If the power supply fan is defective or if the speed control doesn´t
work correctly, the outputs 24 V and 17/75 V are switched off ap-
prox. 10 s after switching the power supply on (overheat protec-
tion). The logic voltage for the CPU board is kept upright.
17/75 V output voltages are missing;
24 V apply over a short term, but are
switched off approx. 10 s after switching
the power supply on.
Overload on 17/75 V, e. g. by short circuit:
Because of the missing supply voltage for the power supply fan,
24 V voltage is also switched off (for safety reasons).
24 V not available
(machine can not initialize correctly, be-
cause the external sensors need 24 V).
The power supply switches off single outputs, if overload and/or
undervoltage occur.
Check if cable A6802 is plugged completely to the 10pin con-
nectors at the power supply and on the CPU board. The cable
plug engages clearly audible to the connector.
Check connected loads for short circuit and/or overload.
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...