Service Manual
ALS/XLS 20x/256/272
02/2019 | 01
211
Impact of the inhibit signal
The description in this chapter only affects the inhibit input at the standard signal interface (in PLC
mode),
not
the inhibit input at the optional applicator interface.
The impact of the inhibit signal on the start signal is influenced by
MACHINE SETUP > On inhibit enter
and
MACHINE SETUP > On inhibit leave
. Combining the settings of the two functions has different
effects.
To simplify the description in the following, abbreviations are used for the settings (see table). „A“
refers to the rising slope, „B“ refers to the dropping slope of the inhibit signal.
[163] Example for setting combination A1B1 and A1B2.
– A = relative position of the product sensor at the time of
rising
signal slope
– A´ = relative position of the dispensing edge at the time of
rising
signal slope
– B = relative position of the product sensor at the time of
dropping
signal slope
– B´ = relative position of the dispensing edge at the time of
dropping
signal slope
Function
Setting
Abbrev.
Signal slope
Effect
MACHINE SETUP >
On inhibit enter
„Do saved starts“
A1
Low-high
Queue is processed
„Del saved starts“
A2
Queue is deleted
MACHINE SETUP >
On inhibit leave
„Do saved starts“
B1
High-Low
Queue is processed
„Del saved starts“
B2
Queue is deleted
A
B
A'
B'
Start signal
Inhibit signal
Product sensor
Dispensing edge
= Product will be labelled
= Product will not be labelled
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...