Service Manual
ALS/XLS 20x/256/272
05/2019 | 05
20
4) Depending on the dispensing edge width.
5) Minimum material width for material with PET liner: 30 mm
6) Minimum material width for material with PET liner: 50 mm
Label sensor
Power supply
7) For more information on fuses, see section
8) Not accessible for user or service technician.
Label roll:
Winding direction
Dispenser (outer) Ø:
Rewinder (outer) Ø:
Core (inner) Ø:
Labels inside or outside
up to 300 mm
up to 200 mm
38.1 / 76.2 / 101.6 mm (1.5 / 3 / 4 ")
Distance to peel edge
L-shape dispensing edge:
V-shape dispensing edge (ALS/XLS 204):
19 mm
77 mm
Sensor type:
Transmission sensor; NPN/PNP (switchable)
System voltage:
ALS/XLS 20x
ALS/XLS 256
ALS/XLS 272
110 V (AC) at 60 Hz power frequency
(permissible tolerance ±10%)
230 V (AC) at 50 Hz power frequency
(permissible tolerance ±10%)
100-240 V (AC) at 50-60 Hz power frequency
(permissible tolerance ±10%)
Power consumption:
ALS/XLS 20x
ALS/XLS 256
ALS/XLS 272
max. 460 VA
max. 560 VA
Fuses:
ALS/XLS 20x
ALS/XLS 256
ALS/XLS 272
F1, F2: T5AH 250 V
7
Fuses integrated in the power supply
8
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...