Service Manual
ALS/XLS 20x/256/272
02/2019 | 00
219
[169] Main circuit for signal inputs (PNP).
1) With 3.8 mA input current
2) With 5.7 mA input current
3) 24 V input
5 V microcontroller input
Circuit diagrams for signal outputs
All signal outputs are designed as PNP and are galvanically separated from the 5 V control system
(optocoupler).
The maximum output power drawable from the 24 V supply is 24 W (1 A). This is the sum of all sen-
sor supplies and of all switch outputs which are active at the same time.
[170] Main circuit for outputs (PNP).
Quantity
Value
Note
Supply voltage
24 V ±10%
V
IL
(state „0“)
5 V
V
IH
(state „1“)
18,0 V @ 3,8 mA
26,4 V @ 5,7 mA
1
2
t
delay
(propagation delay)
60 µs
3
t
debounce
(software debouncing)
10 ms
[Tab. 54] Switching level definitions for signal inputs.
Connection
Maximalstrom
Applicator
0.5 A each power output
Maschine status
0.5 A each power output
[Tab. 55] Maximum ouput current.
1k6
24 V
GND
470R
1k6
Applicator Interface
PNP
Sensor
24 V
Load
GND
GND
Applicator Interface
5 V