Installation and Deinstallation
Adjusting the Novexx sensor
Press the button [37A] for 2 s, until the status LEDs
[37B] light permanently.
–
Notice
: Don´t press the button for longer than 5 s,
otherwise you risk to switch between NO/NC
1
, see
Switching the Novexx sensor - NC/NO
– After releasing the button, a teaching „time window“
opens for 2-8 s. During this period, the status LEDs
are flashing fast [38].
While the LEDs are flashing, move as many label
gaps as possible (at least 2) through the sensor fork.
– The movement direction of the label gap is irrele-
vant, that is the same label gap may be moved back
and forth several times.
– The label gaps have to be moved
manually
,
not
by
pressing the
button.
– If the label gaps were detected successfully, the sta-
tus LEDs are flashing 2x [39].
– If the label gaps were not detected ideal, the status
LEDs are flashing 4x.
Repeat the procedure, if the label gaps were not de-
tected ideal.
1. NO = Normally open; NC = Normally closed (default setting)
[37] Starting the autoteaching.
[38] Autoteaching is indicated by flashing LEDs.
[39] Sensor is successfully set = flashing 2x.
m
in
. 2 s
A
B
2-8 s
mi
n. 2x
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...