Service Manual
ALS/XLS 20x/256/272
02/2019 | 01
209
Signals for PLC connection
Required setting:
SIGNAL INTERFACE > Interface mode
= „PLC signals“.
[159] Pin assignment D-Sub15 connector
[160] Pin assignment M12 socket (fem. connector; output signals). Matching connector: article no. A8144.
[161] Pin assignment M12 socket (male connector; input signals). Matching connector: article no. A8145.
Signal name
Function
Inhibit
Input
If the signal is active, start signals at both signal interfaces (standard and AI) are
ignored. Triggering via
-button is possible.
AI installed: alternatively, the Inhibit input at the AI can be activated (
SIGNAL IN-
TERFACE >ACTIVE INPUTS > Inhibit signal
= „Opt. appl.interf“)
Warning In
Input
An external warning status can be signaled by OR-link at the warning output
Error In
Input
An external error status can be signaled by OR-link at the error output
Ready
Output
Active in dispensing mode (online or online settings)
Not active in configuration mode (offline inclusive error status) and in tandem
mode at the deactivated machine
I
out
< 500 mA
1)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Error
Ready
Dispense End
Warning
GND
GND
GND
GND
+24 V
Error In A
Warning In A
Inhibit A
Error In K
Warning In K
Inhibit K
Ready 4
GND 3
Error 2
8 Warning
5 GND
6 Dispense End
1 GND
7 GND
Error In A 6
GND 7
Inhibit K 1
8 +24 V
5 Error In K
4 Warning In A
2 Inhibit A
3 Warning In K
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...