Power filter:
Mount the power filter direct at the power supply.
Connect the filter casing to the EMC grounding via large metal surfaces.
Lay all lines as close as possible to metal parts, even reserve cable:
– Freely hanging lines act as transceiver antennas.
Ground all reserve cables and unused wires in the cables at least at one end.
Keep the cables as short as possible:
– Cable resistance and signal distortion increase with the length of the cable.