Service Manual
ALS/XLS 20x/256/272
02/2019 | 02
83
Dispense counter function
– Enables dispense counter (displayed during labelling) to be adjusted by pressing the
and
buttons.
Disp. Cnt. Reset function
– Settings: [
No
, Yes]
Yes: Dispense counter is set to zero.
No: Dispense counter is not set to zero.
Factory settings function
– All functions are factory set to values depending on the relevant machine type. This factory set-
ting can be reinstalled at any time.
– All function settings are overwritten by the factory setting.
– Settings: [
No
, „Custom defaults“, „Factory defaults“]
No: No factory setting
„Custom defaults“: If customer specific function settings have been stored previously (see func-
tion
Custom defaults
) those are reinstalled. „Custom defaults“
is only visible, if customer settings have already been stored.
„Factory defaults“: The function settings are reset to the factory setting.
Custom defaults function
– Settings: [„Apply current“, „Delete“]
„Apply current“: Stores the current function settings as default values. The stored settings are
reinstalled by calling
MACHINE SETUP > Factory settings
= „Custom defaults“.
„Delete“: Deletes the stored, customer specific settings. „Delete“ is only visible, if settings have
already been stored.
Store Parameters function
– Saves the settings of the functions to a file on the CompactFlash card (“FORMATS\” directory)
– Settings: [“
With adjust para
“, „Without adj. par”]
“With adjust para” Parameters that contain device-specific settings are
included
in what is
saved. The names of the relevant parameters are marked with a * in the text file.
Default file name:
„SETUPALL ALS xxx yy zzzzzzzzzzzzzzzz.FOR“.
Application
:
Service
“Without adj. par”: Parameters that contain device-specific settings are excluded from what is
saved.
Default file name:
„SETUP ALS xxx yy zzzzzzzzzzzzzzzz.FOR“. Application: Transferring settings to other devices
(when device-specific settings should not be overwritten).
xxx = Machine type, e. g. 306
yy = RH or LH
zzzzzzzzzzzzzzzz = Serial number of the CPU board
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...