Service Manual
ALS/XLS 20x/256/272
02/2019 | 01
236
5145
Rewinder full
The maximum permitted diameter
(205 mm) for the rewinder roll has
been reached.
Remove the rewound backing pa-
per
This error can only occur if the
end of a new label roll was
glued on to backing paper
that had already been wound
onto the rewinder.
Press the
button to confirm
the error message.
5147
Tandemsynch.init
This message can only
appear during tandem opera-
tion at the
master
machine.
– Communication between the mas-
ter and slave machines is not func-
tioning.
Check tandem interface cable.
– Is it a) in place and b) correctly
connected?
Check the settings on both ma-
chines.
– See
5148
Tandemsynch.init
This message can only
appear during tandem opera-
tion at the slave machine.
– Communication between the mas-
ter and slave machines is not func-
tioning.
Check tandem interface cable.
– Is it a) in place and b) correctly
connected?
Check the settings on both ma-
chines.
– See
5151
Applic. interf.
Applicator interface is missing or not
connected.
Connect and/or install applicator
interface.
5152
Winding direct.
– The backing paper end is not cor-
rectly attached to the rewinder
mandrel.
– Wrong machine type selected
(
MACHINE SETUP > Dispenser type
)
Attach the backing paper web to
the rewinding mandrel as de-
scribed in the user manual.
Setting „RH“ at a LH machine or
vice versa.
5200
Home position
This message may appear
when operating the applica-
tor. The applicator did not
reach its home position (upper end
position) within the intended time-
frame.
– Applicator operation set, but no
applicator available.
– The applicator is stuck
– Compressed air applicator: Com-
pressed air supply interrupted or
switched off
– Cable not correctly connected.
Set
SIGNAL INTERFACE
>
Interface
mode
to „PLC interface“.
Remove any obstructions
Check compressed air connection
and reconnect correctly if neces-
sary
Check cable and connect correctly
if necessary.
5201
Touch Down
The applicator lower end position
(Touch Down) was not reached in
time.
Status Status text
Cause
Action to take
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...