Service Manual
ALS/XLS 20x/256/272
05/2019 | 05
22
Internal Interfaces
Status messages, test functions, product profiles
Dimensions
10) Measurements without the dispensing edge bracket and dispensing edge
Data interfaces:
Serial:
Ethernet:
USB:
Memory cards:
Control panel interface:
RS232C (Sub-D9), max. 115 200 Baud
10/100 BaseT (RJ45)
(Gen. 1+2) Device V1.1, USB B, ‘Full speed’
operating mode, 12 MBit/s
9
(Gen. 2) Host, USB-A
(Gen. 1) Slot for 1 CompactFlash card
RS 485 (Mini DIN 6 connection) for remote
control
Applicator Interface
Connection for Applicator Interface (AI) board
(special equipement)
Connector for additional motor driver
not used
Automatic halt, if
... the label roll is spent or no gap was found.
...the max. admissible number of missing labels
is reached.
Test functions:
Automatic diagnostics check when switched on
Output of system data via data interface
Status indicators:
Label counter
Operating hours counter
Storage locations for product profiles:
up to 16
Width x height x depth:
10
ALS/XLS 204
ALS/XLS 206
ALS/XLS 256
ALS/XLS 209
ALS/XLS 272
492 x 488 x 371 mm
492 x 488 x 402 mm
492 x 488 x 402 mm
492 x 488 x 505 mm
492 x 488 x 352 mm
Weight:
ALS/XLS 204
ALS/XLS 206
ALS/XLS 256
ALS/XLS 209
ALS/XLS 272
36 kg
38 kg
40 kg
41 kg
31 kg
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...