Not every applicator uses the same signals: See chapter
Signal name
Function
Home
Input
Active, if the applicator has reached the home position (application is finished)
Touch Down
Input
Use with sensor-controlled applicators (e. g. LTP)
Active, if the applicator touches the product
Cylinder
Output
Controls the pneumatic cylinder of the applicator
Active during the dwell time or until touch down
Duration setable with:
SIGNAL INTERFACE >APPLIC. SIGNALS > Dwell time
Airstream
Support
Output
Controls the airstream, which presses the label against the applicator plate.
Active after the start signal until start of application (cylinder)
Vacuum
Output
Controls the vacuum at the applicator plate
Active after the start signal until end of application (cylinder)
Blow On
Output
Controls the blow-on valve of the applicator
Active after end of application (cylinder)
Duration setable with:
SIGNAL INTERFACE >APPLIC. SIGNALS > Blow on time