LA-BO
[158] Pattern of control signals over time for the setting
Applicator type
= „LA-BO“.
A
Duration is determined by the label length and dispensing speed. „Airstream Support“ switching to low means the
label is dispensed.
B
Can be adjusted via “Blow on time”.
C
The output signal „Offline“ follows the input signal „Inhibit“.
D
The start signal is ignored because of the active „Inhibit“.
Additional signals available with optional Applicator Interface:
Start signal
Airstream
support
Blow on
(setable)
Cycle
Inhibit
Offline
A
C
D
B