Service Manual
ALS/XLS 20x/256/272
02/2019 | 03
49
Installation and Deinstallation
Switching the Novexx sensor - NC/NO
This light sensor is equipped with a push-pull output
stage, thus, the two states are called NO (normally
open) and NC (normally closed).
Default setting: NC
Switching between NC/NO:
Press the button [40A] for at least 6 s, until the status
LEDs [40B] flash 2x.
Finding out the current setting:
Move some label material through the sensor fork
and watch the LEDs.
Compare the result with the table:
Mode
Label
LED
Output
Wenglor (NPN)
Yes
On
Low
No
Off
High
Novexx (NO)
Yes
On
High
No
Off
Low
Novexx (NC)
Yes
Off
Low
No
On
High
[Tab. 4] Overview: LED activity and output levels with or without
Label.
[40] Switching the Novexx sensor between NC and NO.
NC/NO min. 6 s