Service Manual
ALS/XLS 20x/256/272
02/2019 | 00
224
Pin assignment for machine status connection
[174] Machine status connection (arrow).
[175] Pinout machine status connection
[176] Position and pin assignment of the internal machine status connection (CN 610).
Signal name
Function
Error
Power output
I
out
< 500 mA
Signal active when an error message appears on the operator panel display
Error
Error GND
Warning
Warning GND
Ready
Ready GND
Cycle
Cycle GND
not used
PLC start
Inhibit
OD sensor in
1
2
3
4
5
6
7
8
9
19 A
20 K
21 A
22 K
23 A
24 K
16 OD sensor
25 Offline
17 OD sensor GND
26 Offline GND
18 not used
10 +24 V
11 GND
12 +24 V
13 GND
14 +24 V
15 GND
PLC start A 2
Inhibit A 4
not used 6
OD sensor 8
+24 V 16
GND 18
OD sensor in A 20
Offline 10
n. c. 12
+24 V 14
1 PLC start K
3 Inhibit K
5 Error
7 Warning
15 +24 V
17 GND
19 OD sensor in K
9 Ready
11 Cycle
13 Key
CN 610
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...