LTP, LTPV, LA-TO BO sensor
The blow on signal is provided by the interface, even though it is not required by this applicator type.
[153] Pattern of control signals over time for the setting
Applicator type
= „LTP - LTPV“ or „LA-TO BO Sensor“.
A
Duration is determined by label length and dispensing speed. „Airstream Support“ switching to low means the label
is dispensed.
B
Duration t is determined by the backwards movement of the applicator. The application cycle ends when the home
position signal is high again
C
Adjustable with “Blow on time” .
D
The output signal „Offline“ follows the input signal „Inhibit“.
E
The start signal is ignored because of the active „Inhibit“.
t
Start signal
Home position
Airstream support
Cylinder
(setable)
Vacuum
Blow on
(setable)
Offline
Cycle
Inhibit
Touch down