5001
No gap found
– Material end, if no outer diameter
(OD) control is activated.
– The maximum limit for missing la-
bels was exceeded (
LABEL SETUP
>
Miss. label tol.
).
– The machine is not correctly set
for the type of label (
MACHINE SE-
TUP
>
Label sens. type
).
– Label length is not correctly set
(
LABEL SETUP
>
Label pitch
).
– Photoelectric label sensor is dirty.
– Photoelectric label sensor is incor-
rectly positioned.
– Photoelectric label sensor is not
connected correctly.
– Photoelectric label sensor is de-
fective.
– Rotary encoder is not adjusted
correctly.
Check the points listed above and
correct if necessary.
Press the
button to confirm
the error message.
5002
Material end
– Material end (if the internal OD-
control is activated).
Insert new label roll.
5009
Start error
– Refers to the standard start sensor
input (M12).
– The device received another start
signal while applying a label.
– Prerequisite:
MACHINE SETUP >
Start
error stop
is set to “On”
.
Check the operation of the labeler;
increase distance between prod-
ucts if required.
Set
MACHINE SETUP >
Start error stop
to “Off”.
5019
Startsig. overrun
– Too high start signal frequency
caused start signal buffer over-
flow.
– Possible causes: Distance be-
tween product sensor and dis-
pensing edge is too high and/or to
high product
Decrease distance between prod-
uct sensor and dispensing edge.
Decrease dispensing/conveyor
speed.
Increase product distance.
Status Status text
Cause
Action to take
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...