Service Manual
ALS/XLS 20x/256/272
02/2019 | 04
242
Repair
TESTS
Sensor test
Call the
SERVICE/DIAGNOS. > Sensor Test
function.
– Display:
alternating with:
– 00.01 = Identification number of the sensor
– 1 = value currently being transmitted by the sensor “Labels”
Press the
button to change to the next sensor in the list
Press the
button to change to the preceding sensor in the list
Sensor Test
00.01 1
Sensor Test
Labels. 1
Sensor ID
Name
Value
Test
00.01
Labels.
(Label sensor)
1 or 0
Move label material through the sensor; a gap
between labels (punch) must cause a change
between 1 and 0. If no change takes place:
Adjust the sensor (
MACHINE SETUP > Sensor
Adjust
)
00.02
Starts.
(Photoelectric product sen-
sor)
1 or 0
Breaking the light beam must cause a change
between 1 and 0.
00.03
Capaci.
(capacitive label sensor)
1 or 0
Move label material through the sensor; a gap
between labels (punch) must cause a change
between 1 and 0.
00.04
Diamet.
(external photoelectric RD
sensor)
1 or 0
Breaking the light beam must cause a change
between 1 and 0.
00.05
APSF f.
(rotary encoder frequency)
xxx Hz
Shows current rotary encoder frequency when
labeller operating with automatic speed adjust-
ment.
Increase/decrease belt speed
– Displayed frequency must increase/de-
crease accordingly
[Tab. 58] Overview for the “MACHINE SETUP > Sensor Test“
Summary of Contents for ALS/XLS 204
Page 2: ......
Page 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Page 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Page 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Page 309: ......
Page 310: ......
Page 311: ......
Page 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...