Check the location where the
system modules, the
telephones, and auxiliary equipment are to be installed. This
includes making sure sufficient space is available to install the
components.
Location requirements
Clean, dry, and well-ventilated
Temperature:
to 50°C (32°F to 122°F)
Humidity: 5% to
non-condensing
Location: at least 4 m (13.1 ft) from equipment such as
photocopiers, electrical motors, and other equipment that can
produce electromagnetic, radio frequency, and electrostatic
interference.
Electrical requirements
Non-switched outlet
ac outlet located not more than 1.5 m (4.9 ft) from the Key
Service Unit (KSU). The actual distance from the KSU to the
Power Bar may vary with additional Trunk and Station
Modules. Do not use an extension cord between the KSU
and the power bar.
For the 110 V system
Dedicated 110-V ac nominal,
15-A minimum
service with third wire ground.
the 220 V system
Dedicated
to 240-V ac nominal,
10-A minimum service with third wire ground.
WARNING
The ac outlet must be equipped with a third wire ground
to avoid electromagnetic interference.
Modular
Guide
Summary of Contents for DR5
Page 2: ......
Page 45: ...Module installation 39 Installing the cable troughs Modular DR5 Installer Guide ...
Page 76: ...70 Telephone relocation and replacement Modular DR5 Installer Guide ...
Page 164: ...158 Set Copy ...
Page 244: ...238 Problems with optional equipment Modular DR5 Installer Guide ...
Page 266: ...260 Glossary Modular DR5 Installer Guide ...
Page 294: ...12 Call Display services Modular DR5 System Coordinator Guide ...
Page 516: ...234 Glossary Modular DR5 System Coordinator Guide ...
Page 526: ...244 Index Modular DR5 System Coordinator Guide ...
Page 529: ... I J I I I I I I ...