![Norstar DR5 Installer'S Manual Download Page 217](http://html1.mh-extra.com/html/norstar/dr5/dr5_installers-manual_1705695217.webp)
Problems with equipment 211
Symptoms at the alarm telephone
The following troubleshooting procedures focus on alarm codes
specific to network configuration.
Alarm telephone shows
arm:
Possible problem
You have configured one or more
one trunk type, but the
Trunk Cartridge in slot Y of Trunk Module X is not that type.
Solution
1.
Reconfigure the Trunk type to match the type of Trunk
Cartridge that has been installed in slot Y of Trunk Module X.
OR
Install a Trunk Cartridge in slot Y that matches the type of
Trunk you have configured.
Alarm telephone shows
P o s s i b l e p r o b l e m
You have configured one or more loop start trunks as
auto-answer, but the hardware on trunk port does not provide
disconnect supervision.
Solution
1.
Reconfigure your auto-answer loop start trunk or trunks as
manual-answer.
OR
If the line number of your auto-answer loop start trunk is 009
or greater, install a loop start Trunk Cartridge with disconnect
supervision in slot Y, trunk port
Z.
OR
If the line number of your auto-answer loop start trunk is
between 001 and 008, install a Version 2 or higher KSU.
Modular
Installer Guide
Summary of Contents for DR5
Page 2: ......
Page 45: ...Module installation 39 Installing the cable troughs Modular DR5 Installer Guide ...
Page 76: ...70 Telephone relocation and replacement Modular DR5 Installer Guide ...
Page 164: ...158 Set Copy ...
Page 244: ...238 Problems with optional equipment Modular DR5 Installer Guide ...
Page 266: ...260 Glossary Modular DR5 Installer Guide ...
Page 294: ...12 Call Display services Modular DR5 System Coordinator Guide ...
Page 516: ...234 Glossary Modular DR5 System Coordinator Guide ...
Page 526: ...244 Index Modular DR5 System Coordinator Guide ...
Page 529: ... I J I I I I I I ...