Problems with lines 217
selected
shows
Possible problem
You have configured a DTMF line to appear at the telephone.
Solution
1.
Reconfigure the line so that it does not appear at any
telephone and configure another line to replace it at the
telephone.
OR
Reconfigure the line as a different type and install trunk
hardware to support the new type of line.
Possible problem
The
system has taken an E&M line out of service
because the far end did not respond to a disconnect signal from
the
system. The symptom would be accompanied by
Event code 263 in the System Test Log.
Solution
1. Check with the operators of the system at the far end and
find out if’their system is operating.
2. Check that your system hardware is receiving signals
properly.
3. Check the trunk between your system and the far end
system for a break.
Possible problem
The
system has detected no response on an E&M line
from the system at the far end. The symptom will be
accompanied by Event code.265 in the System Test Log.
Solution
1. Check with the operators of the system at the far end and get
them to troubleshoot their system.
Modular DR5 Installer Guide
Summary of Contents for DR5
Page 2: ......
Page 45: ...Module installation 39 Installing the cable troughs Modular DR5 Installer Guide ...
Page 76: ...70 Telephone relocation and replacement Modular DR5 Installer Guide ...
Page 164: ...158 Set Copy ...
Page 244: ...238 Problems with optional equipment Modular DR5 Installer Guide ...
Page 266: ...260 Glossary Modular DR5 Installer Guide ...
Page 294: ...12 Call Display services Modular DR5 System Coordinator Guide ...
Page 516: ...234 Glossary Modular DR5 System Coordinator Guide ...
Page 526: ...244 Index Modular DR5 System Coordinator Guide ...
Page 529: ... I J I I I I I I ...