5. Place a shallow catch basin below the water
solenoid, turn on floor scrubber and activate
conventional solution flow by squeezing the
handle assembly.
NOTE: Attaching a zip tie will assist in holding
the handle while making adjustments to the water
solenoid.
6. Turn the solenoid valve stem completely counter
clockwise for maximum water flow.
7. Slowly turn the valve stem clockwise until water
flow stops.
Stop immediately when water flow
stops.
This is the no-flow or clockwise knob
setting.
8. Reinstall the adjustment knob against the stop
pin as shown below. Tighten set screws (2).
NOTE: Tighten one set screw and then rotate the
knob to gain access to the other set screw.
9.
Reconnect PTC (Push-To-Connect) fitting
to water solenoid valve, cut zip tie securing
bail handle, and reconnect transaxle motor
connection. Adjustment is complete.