62
SS300 Service Information (3-2017)
TROUBLESHOOTING
VACUUM FAN ON
From E-S
top
Swit
ch B+
D-2
M3B
30
87
(2) 12 VDC Batteries
1/RED
1/RED
15/GRN
29/WHT
13/BLK
13/BLK
38/GRY
3/ORA
13/BLK
+
-
+
-
12 Volt
12 Volt
Battery Po
Battery Negative -
PMC021
CB6 (20A)
Vacuum Fan
Motor
MTR
M3A
86
85
Vacuum Fan
Relay
SW-8 Squeegee
Position Switch
(Closed= Down)
Vacuum Fan
Enabled
•
Squeegee Lowered
Disabled
Operational Matrix:
• Squeegee Raised
• Battery Charger ON Interlock