46
SS300 Service Information (3-2017)
TROUBLESHOOTING
BDI (Battery
Discharge
Indicator)
☼ = Flashing
Pro-Panel
LCD
Faults
(Option)
Fault Condition
Reason
Correction
☼ ☼ ☼ ● ●
0xF100
Charger Generic
Warning
1. Error condition has occurred with
charger unit.
Replace charger.
● ☼ ☼ ● ●
0xF101
Charger No Load
Warning
1. Battery pack may not be plugged
into charger.
2. Charger is bad.
1. Verify batteries are connected
properly.
2. Verify wire harness continuity.
3. Replace charger.
● ☼ ● ● ●
0xF102
Charger
Overheat
Warning
1. Charger environment is not cool
enough and cannot complete charge.
2. Charger is faulty.
1. Move machine to well-
ventilated area.
2. Replace charger
● ☼ ☼ ● ☼
0xF104
Charger Timer
Phase I Warning
1. Batteries not charging correctly.
Check for low battery voltage.
☼ ● ☼ ● ●
0x0703
EC-H2O Breaker
Tripped Warning
1. Detected module circuit breaker
trip.
2. Scrub Controller board J4
connector unplugged.
3. Scrub Controller board J4
connector pin 2 disconnected.
Power cycle machine. Check
connections.
0x0712
EC-H2O Pump
Breaker Tripped
Warning
1. Detected module circuit breaker
trip.
2. Scrub Controller board J4
connector unplugged.
3. Scrub Controller board J4
connector pin 1 disconnected.
Power cycle machine. Check
connections.
● ☼ ● ☼ ●
0x0711
EC-H2O Pump
Open Warning
1. Wiring, connector, or control board
issue on ec-H2O pump.
Control board is not detecting
pump current. Check
connections for voltage and
verify pump is operating.
● ☼ ☼ ☼ ☼
0x0713
EC-H2O Pump
Over Current
Warning
1. Current draw higher than expected.
Check pump operating current.
0x0717
EC-H2O Control
board failure /
damage
1. EC Module control board is
damaged.
Replace the NanoClean
Controller kit.
FAULTS (Cont’d)