36
SS300 Service Information (3-2017)
TROUBLESHOOTING
TROUBLESHOOTING
FAULTS
Machine faults are displayed three different ways
depending on the machine configuration:
Machines equipped with a membrane panel display
faults using the BDI (Battery Discharge Indicator). If
a fault is present, the BDI displays a combination of
flashing and steady LEDs, which can be interpreted
using the tables below.
Machines equipped with the optional LCD panel offer
additional fault detail. Note that in the table below
some BDI faults correlate to several LCD fault codes
that are more specfic as to the circuit causing the fault.
A Service Diagnostics tool is available to provide ad-
ditional fault detail. See “SERVICE DIAGNOSTICS
TOOL in the SERVICE section of this manual.
BDI (Battery
Discharge
Indicator)
☼ = Flashing
Pro-Panel
LCD
Faults
(Option)
Fault Condition
Reason
Correction
0x0010
Parking Brake
Flashing indicator alerts that manual
parking brake is engaged on wheel.
Release parking brake.
☼ ☼ ☼ ☼ ☼
0x
E-Stop activate
fault
1. E-Stop pressed.
2. Large white iDrive connector
unplugged.
3. Large white iDrive connector pin 7
disconnected.
4. IDrive power wire unplugged.
5. Scrub controller board connector J9
pin 2 disconnected.
6. Scrub controller board connector J8
unplugged.
7. Scrub controller board connector J8
pin 7 disconnected.
1. Key off machine.
2. Press and reset E-Stop
button.
3. Key on machine.
4. If fault persists, check
harness connections between
E-Stop and control module.
5. Replace or repair harness.
6. Replace E-Stop.
● ● ● ☼ ●
0x0201
Actuator Open
Warning
Wiring, connector, or control board
issue on actuator.
Check connectors and
connector pins.
● ● ● ☼ ☼
0x0101
Scrub Motor
Open
Warning
1. Wiring, connector or control board
issue on scrub motor.
2. J10 connector on scrub
controller board unplugged.
3. Scrub controller board power
disconnected.
4. Scrub controller inline power fuse
defective/blown.
5. Scrub controller board problem.
Check connections. Board gets
power from key switch and
battery. If connections are good,
replace control board.