38
SS300 Service Information (3-2017)
TROUBLESHOOTING
FAULTS (Cont’d)
BDI (Battery
Discharge
Indicator)
☼ = Flashing
Pro-Panel
LCD
Faults
(Option)
Fault Condition
Reason
Correction
☼ ● ● ● ☼
0x0900
Propel Generic
Fault
1. Generic iDrive fault.
2. Large white iDrive connector pin 2,
8, or 9 disconnected.
3. User Interface speed pot connector
unplugged.
Power cycle machine. Check
connections/wiring.
0x0903
Propel
Communication
Lost Warning
1. Large white iDrive connector pin 5
disconnected.
2. Small white iDrive connector
unplugged.
3. Small white iDrive connector pin 3
or 4 disconnected.
4. Scrub controller board connector J2
or J8 unplugged.
5. Scrub controller board J9 pin 1 or 2
disconnected.
6. Scrub controller board J8 pin 7
disconnected.
7. Smaller of two console connectors
unplugged.
8. User Interface board connector J4
or J9 unplugged.
Power cycle machine. Check
connections/wiring.
0x0904
Propel Power
Cycle Needed
1. iDrive just programmed by service
tech with new parameters.
2. iDrive unit is faulty.
Power cycle machine. Replace
iDrive.
0x0905
Propel Current
Limit Fault
1. Controller detects motor is drawing
excessive current.
Check motor, connectors, and
relevant wiring to controller. If
trip is still present after motor,
connectors, and wiring have
been checked, the controller
may be defective. Replace
controller.
0x0908
Propel RAM
Check Error
iDrive unit is faulty.
Replace iDrive.
0x0909
Propel Data
Check Error
iDrive unit is faulty.
Replace iDrive.
0x090A
Propel Tiller Low
Reference
Controller detects Throttle Low
Reference is outside of normal range.
Throttle Low Reference is located on
pin 8 of 14-way Tiller Connector.
Check throttle potentiometer,
connectors, and relevant wiring
to controller. If trip is still present
after potentiometer, connectors,
and wiring have been checked,
controller may be defective.
Replace controller.
0x090B
Propel Gone to
Sleep
Controller enters Sleep Mode.
Turn controller off and then
on to wake system. To
disable Sleep Mode, program
parameter Sleep Timer to 0
minutes.