SS300 Service Information (3-2017)
33
MAINTENANCE
4. 4. Rotate the rear blade to a new wiping edge (Fig.
115). Make sure to align the slots in the blade with
retainer tabs.
Fig. 115
5. 5. Squeeze the squeegee frame and blade
retainer together and re-tighten the two outside
knobs (Fig. 116).
Fig. 116
ec-H2O NanoClean WATER CONDITIONING
CARTRIDGE REPLACEMENT
FOR SAFETY: Before leaving or servicing
machine,
stop on level surface, turn off machine,
remove key and set parking brake if equipped.
The water conditioning cartridge is required to be
replaced when it reaches its maximum water usage or
expiration time of when the cartridge was activated,
which ever comes first. The control panel will signal a
code when it’s time to replace cartridge.
Depending on machine usage, on average, a new
cartridge can last anywhere from 12 months for heavy
machine usage to 24 months for light machine usage.
ATTENTION: During first time use and after
replacing the water conditioning cartridge, the
ec-H2O system will automatically override the
selected solution flow rate for up to 75 minutes.
1. Park the machine on a level surface, remove the
key and set parking brake, if equipped.
2. Lift the recovery tank to access the ec-H2O water
conditioning cartridge (Fig. 117). Drain recovery
tank before lifting tank.
Fig. 117