SS300 Service Information (3-2017)
43
TROUBLESHOOTING
BDI (Battery
Discharge
Indicator)
☼ = Flashing
Pro-Panel
LCD
Faults
(Option)
Fault Condition
Reason
Correction
☼ ● ● ● ☼
0x093C
Propel Trip Latch
Not Armed
iDrive unit is faulty.
Replace iDrive.
0x093D
Propel Failed To
Arm Trip Latch
iDrive unit is faulty.
Replace iDrive.
0x093E
Propel Trip
Latch Became
Unarmed
iDrive unit is faulty.
Replace iDrive.
0x093F
Propel Left Motor
Shorted Low
iDrive unit is faulty.
Replace iDrive.
0x0940
Propel Controller
Fault
Each time controller trips with a
suspected controller error, it records
one instance of code ‘4401’ in
controller System Log. Actual
controller trip code is also recorded
in controller Control Log. Number
of ‘4401’ trips shown in System Log
should equal cumulative number of
trip occurrences shown in Control Log.
If controller continues to trip
after batteries, connectors, and
wiring have been checked,
controller may be defective.
Replace controller.
0x0941
Propel Soft Belly
Button Active
Controller detects Belly Button Switch
has been operated at power-up.
Check Belly Button Switch,
connectors, and relevant wiring
to controller. If trip is still present
after switch, connectors, and
wiring have been checked,
controller may be defective.
Replace controller.
0x0942
Propel Internal
Temperature
Sensor
iDrive unit is faulty.
Replace iDrive.
☼ ● ● ☼ ●
0x0906
Propel Motor
Short Low Fault
Controller detects motor wiring has
been shorted to Battery Negative.
Check motor, connectors, and
relevant wiring to controller. If
trip is still present after motor,
connectors, and wiring have
been checked, controller may
be defective. Replace controller.
0x0907
Propel Motor
Short High Fault
Controller detects motor wiring has
been shorted to Battery Positive.
Check motor, connectors, and
relevant wiring to controller. If
trip is still present after motor,
connectors, and wiring have
been checked, controller may
be defective. Replace controller.
FAULTS (Cont’d)