16
SS300 Service Information (3-2017)
GENERAL INFORMATION
FUNCTION
ENABLED
OPERATIONAL MATRIX
DISABLED
Vacuum Fan
• Squeegee Lowered
• Squeegee Raised
• Low Battery Voltage
(Wet < 21.9 V, AGM < 22.7 V)
• Fault
• Battery Charger ON Interlock
Main Scrub Motor
• Head Lowered - Foot Pedal
• Fwd/Rev Throttle Command or Bail
activated on non-propel models.
• Head Raised - Foot Pedal
• Neutral - Ready State or bail released on
non-propel models.
• Low Battery Voltage
(Wet < 21.9 V, AGM < 22.7 V)
• Fault
• Battery Charger ON Interlock
MOM001_1
Propel (drive option)
• Fwd/Rev Throttle Command
• Fwd/Rev Switch Input
• Neutral - Ready State
• Propel Motor Controller Fault
• Battery Charger ON Interlock
Solution Control
(ec-H2O NanoClean - option)
• Head Lowered - Foot Pedal
• Solution Control ON
• ecH2O Switch ON
• Fwd/Rev Throttle Command or Bail
activated on non-propel models.
• Head Raised - Foot Pedal
• Solution Control OFF
• ecH2O Switch OFF
• Neutral - Ready State or bail released on
non-propel models.
• Low Battery Voltage
(Wet < 21.9 V, AGM < 22.7 V)
• ecH2O System Fault
• Battery Charger ON Interlock
Solution Control
(Conventional)
• Head Lowered - Foot Pedal
• Solution Control ON
• Fwd/Rev Throttle Command or Bail
activated on non-propel models.
• Head Raised - Foot Pedal
• Solution Control OFF
• Neutral - Ready State or bail released on
non-propel models.
• Low Battery Voltage
(Wet < 21.9 V, AGM < 22.7 V)
• Fault
• Battery Charger ON Interlock