44
SS300 Service Information (3-2017)
TROUBLESHOOTING
BDI (Battery
Discharge
Indicator)
☼ = Flashing
Pro-Panel
LCD
Faults
(Option)
Fault Condition
Reason
Correction
☼ ● ● ☼ ☼
0x0103
Scrub Motor
Over Current
Fault
1. Current draw higher than expected.
2. Higher current draw than hardware
design limit.
Verify floor, pad, and down
pressure combination are
appropriate for machine.
Check actuator.
0x0104
Scrub Motor
Over Current 1
Fault
1. Current draw higher than expected.
Verify floor, pad, and down
pressure combination are
appropriate for machine.
Check actuator.
0x0105
Scrub Motor
Over Current 2
Fault
1. Current draw higher than expected.
Verify floor, pad, and down
pressure combination are
appropriate for machine.
Check actuator.
☼ ● ☼ ● ☼
0x0902
Propel High
Throttle Fault
1. Bail is activated before turning on
machine.
2. Bail did not release to full rest
position due to obstruction.
Controller detects Throttle
Potentiometer has been displaced
at start-up and parameter Throttle
Operated At Power-Up has been set
to ‘Trip’.
1. Release bail.
2. Key off and on.
3. If error persists, check for
obstruction or damaged bail
switch.
4. Replace switch or bail handle
if damaged.
☼ ● ☼ ☼ ●
0x0107
Scrub Motor FET
Fault
1. Power/battery issue on startup.
2. Control board problem.
1. Check harness/module
power and ground connections.
2. Replace Control board.
0x0207
Actuator FET
Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor,
actuator, detergent pump,
vacuum, and battery watering
pump.
0x0507
Vacuum FET
Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor,
actuator, detergent pump,
vacuum, and battery watering
pump.
0x0607
Detergent Pump
FET Fault
1. Control board problem.
2. Power/battery issue on startup.
Replace control board. FET
detection includes motor,
actuator, detergent pump,
vacuum, and battery watering
pump.
FAULTS (Cont’d)