82
SS300 Service Information (3-2017)
SERVICE
Fig. 118
Dial
Position
Battery Description Settings with AH
Ranges
0
Factory setting* Programmed via CAN-
Bus
1
Wet, Trojan 105- 155 AH
2
Wet, Enersys/Tab 105- 155 AH
3
AGM, Discover 80- 150 AH
4
AGM, Fullriver 80- 150 AH
5
AGM, TPPL, Enersys 20- 40 AH
6
Gel, Sonnenschein 80- 150 AH
*The CAN-BUS setting, dial position “0”, is the soft-
ware setting that is programmed to match battery
type supplied with machine. When the dial is manu-
ally changed to a different setting, it should not be re-
set back to “0” otherwise battery damage may result.
Service Application Software is required to reset dial
back to “0”. Contact Service.
7. Replace the black cap on charger, reinstall
battery
charger and replace control console.
8. Reconnect the battery cable connection.
9. To set the BDI for the new battery type, plug the
on- board battery charger cord into an electrical
outlet. The machine’s software will automatically
reprogram the BDI to the new battery type.
CHANGING ON-BOARD BATTERY CHARGER
SETTINGS (Pro-Panel model)
NOTE: To perform this procedure, machine must be
in supervisor mode. See SUPERVISOR CONTROLS
instructions at back of manual.
To change the on-board battery charger settings for a
different battery type :
1. Turn the key to the on position.
2. Press the settings button located on the home
screen (Fig. 119).
Fig. 119
3. Press the Setup button to access the Setup
screen (Fig. 120).
Fig. 120