29
Installer’s Guide
Nobeltec InSight Radar (IR2)
Cable #4: Ethernet Connector Cable
Cable #4: Ethernet Cable
From Control Box to PC
No
Function
1
RD+
2
RD-
3
TD+
4
Termination
5
Termination
6
TD-
7
Termination
8
Termination
9
Ground 1
10
Ground 1
Figure 2.18 Cable #4: Control Box rear view.
The Ethernet connector cable is discussed in greater length in the next chapter.
Changing the Dip Switch Settings
The dip switch settings are set at the factory and should not need to be changed.
However, changing the dip-switches may be necessary to optimize and/or customize
an installation. For example, on a direct connect installation, you may turn S1-
1 off to disable the DHCP client. Changing this eliminates the one-minute delay
before the radar is available due to DHCP activity. Additionally, you may need to
change the default IP address of the radar to prevent conflict with other devices in a
network. Please contact Nobeltec before changing these settings.
Record any changes made to the switches in the column labeled New Value below.
Warning
: Electronic circuits and memories are sensitive to static
shock. Make sure that you are grounded to a static pad before
opening the box and making any changes.
Hardware Installation
Summary of Contents for InSight Radar 2
Page 2: ......
Page 6: ......
Page 26: ...20 Nobeltec InSight Radar IR2 Installer s Guide Hardware Installation...
Page 64: ...58 Nobeltec InSight Radar IR2 Installer s Guide Dimensions and Weight IR2 4D Specifications...
Page 65: ...59 Installer s Guide Nobeltec InSight Radar IR2 IR2 4 3 and IR2 4 4 Specifications...
Page 67: ...61 Installer s Guide Nobeltec InSight Radar IR2 IR2 25 4 IR2 25 6 and IR2 25 9 Specifications...
Page 74: ......
Page 75: ......
Page 76: ......