Chapter 1 System Configurations and Part Names
1.4 Name of Each Part
1-62
1.4.6
Laser Safety Kit
The laser safety kit is supplied with all laser products mounted onto a Ti microscope.
Labels affixed to each laser product include a name label and other types of necessary labels, both of which
are not shown here.
The laser safety kit is composed of the filter slider cover, protection plate for nosepiece, filter cube port cover
retaining plate, and safety labels, “(7) IEC caution label – Class 3B areas” and “(9) IEC aperture label”.
Before using the microscope, CHECK that each part of the laser safety kit is correctly attached. (See the
figure below.)
(7) IEC caution label -Class 3B areas
CAUTION – CLASS 3B
LASER RADIATION WHEN OPEN
AVOID EXPOSURE TO THE BEAM
VORSICHT – LASERSTRAHLUNG
KLASSE 3B,
WENN ABDECKUNG GEÖFFNET
NICHT DEM STRAHL AUSSETZEN
LAS
ER
RA
DIA
TIO
N
AVO
ID E
XPO
SU
RE
TO
BE
AM
CLA
SS
3B
LAS
ER
PR
OD
UC
T
AVO
ID E
XPO
SU
RE
LAS
ER
LIG
HT
IS
EM
ITT
ED
FRO
M O
BJE
CTI
VE
APE
RTU
RE
CAUTION – CLA
SS 3B
LASER RADIAT
ION WHEN OPE
N
AVOID EXPOSU
RE TO THE BEA
M
VORSICHT – L
ASERSTRAHLU
NG
KLASSE 3B,
WENN ABDEC
KUNG GEÖFF
NET
NICHT DEM STR
AHL AUSSETZE
N
AVOID EXPOSU
RE
LASER LIGHT
IS EMITTED
FROM THIS AP
ERTURE
CAUTION – CLA
SS 3B
LASER RADIAT
ION WHEN OP
EN
AVOID EXPOS
URE TO THE B
EAM
VORSICHT – L
ASERSTRAHLU
NG
KLASSE 3B,
WENN ABDEC
KUNG GEÖFF
NET
NICHT DEM ST
RAHL AUSSET
ZEN
CAUTION – CL
ASS 3B
LASER RADIAT
ION WHEN OP
EN
AVOID EXPOS
URE TO THE B
EAM
VORSICHT – L
ASERSTRAHLU
NG
KLASSE 3B,
WENN ABDEC
KUNG GEÖFF
NET
NICHT DEM ST
RAHL AUSSET
ZEN
ON
OFF
6V30W
MAX.
12V100W
Figure 1.4-49
(9) IEC aperture label 2
AVOID EXPOSURE
LASER LIGHT IS EMITTED
FROM THIS APERTURE
Figure 1.4-50
Filter slider cover
The filter slider cover is a component designed for preventing unintended exposure of eyes or skin at the
slider port to laser light emitted to the dia-pillar illuminator. To attach it to the Ti microscope, lay it over the
dia-pillar illuminator and secure it with the screws and nuts provided with the kit.
Filter cube port cover retaining plate
The filter cube port cover retaining plate is a component designed for preventing accidental leakage of laser
light upon occurrence of unintended opening of the filter cube port cover.
Attach it to the side of the epi-fl filter turret’s lower plate using the screws provided with the kit.
Safety labels
The label (7) affixed to the upper left side (when viewed from the Binocular eyepiece tube) of the dia pillar
indicates that the laser light may come out from the aperture when the lamphouse is removed for
replacement of the lamp inside.
Another labels (7) on both sides of the microscope base indicates that the laser light may come out from the
aperture while attaching the epi-fl filter turret or the nosepiece to the microscope.
The labels (9) on both sides of the microscope base indicates that the laser light may come out of the
analyzer port.
Filter cube port
cover retaining plate
Filter slider cover
Safety label (7)
(Both sides)
Safety label (9)
(Both sides)
Dia pillar illuminator
Safety label (7)
Analyzer port
Protection plate
(for nosepiece)
Summary of Contents for Eclipse Ti Series
Page 2: ......
Page 14: ......
Page 256: ......
Page 258: ......
Page 260: ...Contents 2 2 8 2 Environmental Conditions 2 70 8 3 Safety Standards Compliance 2 71 ...