MO
motor on
IMM PGM MIP
USAGE
♦
♦
♦
SYNTAX
xx
MO
or xx
MO
?
PARAMETERS
Description
xx
[ int ]
-
axis number
Range
xx
-
to
MAX AXES
Units
xx
-
none
Defaults xx
missing:
error 37, AXIS NUMBER MISSING
out of range:
error 9, AXIS NUMBER OUT OF RANGE
DESCRIPTION
This command turns power ON of the specified motor (axis).
CAUTION
If the motor power was turned off by the controller detecting a fault
condition, before turning the power back on, make sure that the cause of the
fault was corrected.
RETURNS
If “?” sign is issued along with command, the controller returns:
1
-
motor power is ON
0
-
motor power is OFF
REL. COMMANDS
AB
-
abort motion
ST
-
stop motion
MF -
urn motor power OFF
EXAMPLE
MO
|
turn axis #2 motor power ON
2MO?
|
query axis #2 motor power status
1
|
controller returns a value of 1
2MF
|
turn axis #2 motor power OFF
2MO?
|
query axis #2 motor power status
0
|
controller returns a value of 0