oPtion
DESCRIPTION
DEFAULt PAgE
P70E
Telephone No.1 for CID reporting
see P170E
NONE
46
P71E
Telephone No.2 for CID reporting
see P171E
NONE
P72E
Account No. 1 for Central Station rpt
0000
46
P73E
Account No. 2 for Central Station rpt
0000
The following options relate to reporting to central station by CID.
See P190E, P191E, P192E, P193E for related SMS reporting options.
P74E
REPORT ZONE ALARMS
All zones
49
P75E
D8 & D16
1E
Report DURESS alarms
OFF
50
2E
Report MEDICAL alarms
OFF
3E
Report keypad & Keyswitch PANIC
ON
4E
Report FIRE alarms
OFF
5E
Report PANEL TAMPER alarms
ON
6E
Report EXTERNAL TAMPER alarms
ON
7E
Report KEyPAD TAMPER alarms
ON
8E
Report EXIT FROM INSTALLER mode
OFF
D8,
p92e
1e
Report RADIO TAMPER
ON
D16,
p75e
9e
D8,
p92e
2e
Report RADIO PANIC by User ID
ON
D16,
p75e
10e
D8,
p92e
3e
Report RADIO Low Battery by device
OFF
D16,
p75e
11e
D8,
p92e
4e
Report ZONE SUPERVISION FAIL
OFF
D16,
p75e
12e
D8,
p92e
5e
Report PANEL LOW BATTERy
ON
D16,
p75e
13e
D8,
p92e
6e
Report MAINS FAIL
ON
D16,
p75e
14e
P76E
Report Zone Restorals
All on
49
P77E
Report Misc. Restorals
All on
50
P78E
Report Multiple Zone alarms
NONE
49
P79E
Account No.2 zones
NONE
49
P80E
Tel No. 3 for Test Calls
see P172E
NONE
P82E
1E
Send RESTORAL report immediately
OFF
50
2E
Send RESTORAL after siren time
OFF
3E
Send RESTORAL after Disarm & seal
OFF
4E
Send RESTORAL after Disarm always
ON
P83E
TEST CALL Interval
84
(168hrs)
51
P84E
Time before NEXT TEST CALL
n/a
P86E
1E
Disable Dialler
OFF
52
2E
Enable reporting by CID
ON
P87E
*
1E
Split dial Primary/Secondary numbers
OFF
53
2E
[not used]
OFF
3E
Enable reporting by SMS
ON
4E
4 Dialling attempts
ON
oPtion
DESCRIPTION
DEFAULt PAgE
P88E
1E
Send AREA 1 Open/Close by CID
OFF
54-55
2E
Send AREA 2 Open/Close by CID
OFF
See P194E for Open/Close by SMS
3E
Siren Chirp on Kiss-off
OFF
4E
Flash Strobe on Kiss-off
OFF
5E
Forced Opening report
ON
6E
Delayed Closing Reports
OFF
7E
Manual Exclude Reports
ON
8E
Auto Exclude Reports
ON
P89E
1E
ENABLE TEST CALLS
ON
56
2E
Mains Report Delay (1 hour)
ON
3E
[not used]
OFF
4E
Swinger shutdown
ON
5E
Line Fault Monitor
OFF
6E
Master Code Clears Dial Attempts
OFF
The following options relate to reporting to central station by CID.
See P191E, P193E for related SMS reporting options.
P92E
Report Misc. Alarms 9-14
(D8 only)
1,2,5,6 on
50
P93E
Report Misc. Restorals 9-14
(D8 only) All on
P94E
“No Memory Warning” zones
none
57
P95E
CLEAR RADIO DEVICES
58
P96E
CLEAR MEMORy
P97E
CLEAR PANEL OPTIONS
(restore Factory Defaults)
P98E
CLEAR User codes, Radio Keys, Access Cards
P99E
Program the INSTALLER CODE
000000
58
P101e-P116e
PROGRAM RADIO DEVICES
1–8 or 1–16
none
78
P117E
1E
Enable Output Expander
OFF
59-60
2E
Expander Output Format A, B
OFF
3E
Day Zone Follower
OFF
4E
Output Exclude
OFF
5E
Expander Output Format C
OFF
6E
User Code Toggle or Pulse
OFF
P118E
Output Expander zones
none
P119E
Output Expander alarm zones
none
P120E
1E
Latched keyswitch input
OFF
61-62
2E
Home arm chirps by radio key
OFF
3E
Radio Key AUX arms Home mode
OFF
4E
Keyswitch DISARM ONLy
OFF
5E
Keyswitch ARM ONLy
OFF
6E
Smart Beeps
(Brief Home & Day modes)
OFF
7E
Entry Delay Extender
OFF
8E
Area2 Disarm by Keyswitch Allowed
OFF
P121E
1E
Zone alarms to AUX1
(p58e selects zones)
ON
63
2E
Zone Supervision alarms to AUX1
OFF
3E
Radio key Panic TOGGLE
OFF
4E
Radio key Panic PULSE
OFF
7E
door Open Too Long (dOTL) alarm to aUX1
OFF
8E
Reader [x] output to AUX1
OFF