ZonE to oUtPUt mAPPing
When a zone alarms, it can turn on any or all outputs: Sonalert, Strobe, Siren, Reset, AUX outputs.
The programming is selected with options P54E – P59E. Simply set the zone number to the output to select it. The zone LED will
indicate if the zone is selected.
The Tamper Input and the Keypad Panic can be programmed to turn on the Reset, Strobe, Sonalert and Siren by using option
P61E.
mAPPing ZonEs to oUtPUts
ZONES 1–8
(D8 & D16)
ZONES 9–16
(D16)
Option No. Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
P54E
RESET Zones
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
P55E
STROBE Zones
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
P56E
SONALERT Zones
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
P57E
SIREN Zones
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
P58E
AUX1,3 Zones
P59E
AUX2,4 Zones
Zone To Output Mapping
applies to zones when the panel is
in the Armed or 24hr state.
For Home and DAy mode Output
Mapping – see Option P63E
1E–8E, page 37.
P54E
rEsEt oUtPUt ZonEs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
All ON: All zones trigger Reset output.
Selects the zones to trigger the Reset output.
KPX+
P54E [Zone Number] E to enable/disable zones
NAVIGATOR
P54E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E P54E [Zone Number] E
Or use
NessXCEL
app
P55E
strobE oUtPUt ZonEs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
All ON: All zones trigger Strobe output.
Selects the zones to trigger the Strobe output.
KPX+
P55E [Zone Number] E to enable/disable zones
NAVIGATOR
P55E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E P55E [Zone Number] E
Or use
NessXCEL
app
P56E
kEyPAD sonALErt ZonEs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
All ON: All zones sound the Keypad
Sonalert.
Selects the zones to trigger the Keypad Sonalert.
KPX+
P56E [Zone Number] E to enable/disable zones
NAVIGATOR
P56E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E P56E [Zone Number] E
Or use
NessXCEL
app
P57E
sirEn ZonEs
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
All ON: All zones trigger Siren output
Selects the zones to trigger the Siren output.
KPX+
P57E [Zone Number] E to enable/disable zones
NAVIGATOR
P57E > Select zones
SMS*
P[MasterCode]E P[InstallerCode]E P57E [Zone Number] E
Or use
NessXCEL
app
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
KPX+
PRO TIP
When selecting zones,
mEmory E
selects all zones,
0 E
deselects all zones
31
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g