AUx4
OUTPUT OPTIONS
Only one of the P124E options may be selected.
Option No.
Description
Default
P124E
1E Zone Alarms to AUX4
OFF
2E Enable Extension Sonalert
OFF
3E
Enable AUX4 for AutoTimer
OFF
4E Radio Key Panic Pulses AUX4
OFF
5E Enable AUX4 Fail To Communicate Output
OFF
6E
[not used]
OFF
7E
[not used]
OFF
8E
Reader output pulses AUX4
OFF
P124E
AUx4 oPtions 1E - 8E
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
1E on.
notEs
Only one option can be on. Turning an
option on turns off another.
rELAtED oPtions
P144E 1E-8E Enhanced AUX4 options.
P374E 7E-8E AutoTimer1 AUX4 options.
P379E 7E-8E AutoTimer2 AUX4 options.
P384E 7E-8E AutoTimer3 AUX4 options.
P389E 7E-8E AutoTimer4 AUX4 options.
P124E is one of several options which control the behaviour of the AUX4 output.
Enable or disable P124E 1E to 8E as required. Only one option can be on.
KPX+
P124E 1E - 8E to enable/disable the option as required
NAVIGATOR
P124E > enable/disable 1E - 8E as required
SMS*
P[MasterCode]E P[InstallerCode]E P124E [1E -8E] as required
Or use
NessXCEL
app
P124E 1E
ZonE ALArms to AUx4
rELAtED oPtions
P59E Aux2/4 zones.
P122E 1E Zone Alarms to AUX2
With this option ON, zones selected in P59E will turn on Aux4 when they go into alarm. The
Aux4 output turns off when the panel is disarmed/reset.
P124E 2E
EnAbLE ExtEnsion sonALErt
notEs
The extension beeper can either be a
standard 12V sonalert or wire directly to the
Ness Quantum Sonic as shown. Keypad
beeps will be heard at low volume from the
Quantum Sonic's onboard siren. (Normal
siren sound is unaffected).
Enables the Aux4 output to duplicate all keypad beeps including keypress beeps. This is
useful in cases where, for example, entry beeps or other keypad beeps need to be heard in
more than one location on the premises. (Adding an additional keypad would also achieve
the same result).
P124E 3E
EnAbLE AUx4 For AUtotimEr
rELAtED oPtions
P370E to P389E. AutoTimers.
When this option is on, AUX4 is enabled for use by AutoTimer.
P124E 4E
rADio kEy PAniC PULsEs AUx4
rELAtED oPtions
P148E AUX4 Timer
When this option is on, Radio Key/s Panic button will PULSE the Aux4 output.
When this option is on, Radio Key Panic buttons will no longer sound alarms or report
alarms by dialler.
Note that P122E 4E (Radio Key Panic Pulses AUX2) over-rides this option.
P124E 5E
EnAbLE AUx4 FAiL to CommUniCAtE oUtPUt
rELAtED oPtions
P370E to P389E. AutoTimers.
When this option is enabled AUX4 will turn on at the start of the fourth dialout attempt.
This can be used as Fail To Communicate output to trigger backup communications
devices such as GSM. The AUX4 output is automatically turned off on the next successful
communication attempt or when the panel is next disarmed.
P124E 8E
rEADEr oUtPUt to AUx4
rELAtED oPtions
P318E, P328E, P338E, P319E, P329E,
P339E.
This option enables an access control reader to pulse AUX4 when a valid access card is
presented. Set the reader using P318E, P328E or P338E.
Any or all of the P144E options may be selected.
Option No.
Description
Default
P144E
1E
Area1 Armed to AUX4
OFF
2E
Area2 Armed to AUX4
OFF
3E
Home Mode arm to AUX4
OFF
4E
Keypad toggle AUX4
OFF
5E
[not used]
OFF
6E
[not used]
OFF
7E
[not used]
OFF
8E
Pulse AUX4
OFF
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
69
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g