rADio CoDEs
Each of the 56 User Codes, except for the Master Code, can be programmed to
be Radio Codes. This allows up to 55 Ness Radio Keys to be used for Arming and
Disarming of the panel. The Ness RKP Radio Keypad can also be used with the
D8/D16, (see the RKP installer manual). The optional 100–200 Ness Radio Interface is
required for radio operation.
PROGRAMMING RADIO KEyS
Use the Extra Options programming mode to enable selected user codes as Radio
Codes. When a user code is enabled as a Radio Code, its Keypad Code, (if any), is
automatically deleted.
PROGRAMMING SEQUENCE:
In Installer Program Mode, enter the option number for the user code which will be
become a radio code. (Example, enter P256E for user code 56).
KPX+
Press EXCLUDE E to enter Extra Options mode. (Exclude icon is on).
NaVIGaTOr
Press Extra Code Options.
KPX+
Press 5E to enable that user code as a Radio Code. (Icon 5 is on).
NaVIGaTOr
Press 5 - Radio Code.
KPX+
EXCLUDE E to exit Extra Options mode. (The Exclude icon is off).
NaVIGaTOr
Press
to exit the Extra Options screen.
KPX+
Press 1E
(The OK icon will turn ON to indicate ready to accept the Radio Key)
NaVIGaTOr
Press
If a code is already programmed the OK icon will not turn on and a warning beep will
sound. To clear the code, press 0E to clear existing codes then go back to step 5.
Press the OFF button on the Radio Key to be programmed
If the Radio Key is accepted, the OK icon will turn off and 3 beeps will sound.
If the OK icon stays on and a warning beep sounds, the Radio Key is already assigned
to another User Code and must be cleared from that User Code first.
PROGRAMMING RADIO KEyS By SMS
SmS
Radio keys can be programmed remotely by SMS but of course somebody must be on site to
initiate the learn signal on the radio key being programmed.
Example, to program a Ness RK4 Radio key as user 56.
The SMS string below enters program mode, selects user 56, enables the radio code, deletes
any existing device, selects learn mode, then the panel will wait for 30 seconds for a learn signal.
At this point you should press the OFF button on the radio key. Once the device is successfully
programmed you will hear 3 beeps from the keypad. The panel will exit program mode on expiry of
the 30 second learn window.
SMS
P[MasterCode]E P[InstallerCode]E P256E XE5EXE 0E 1E
When the keypad displays
READy TO RECEIVE / OK
, press the OFF button on the radio key.
to DELEtE A rADio CoDE
Any Radio Code can be deleted as
required.
Delete a radio code if a) the radio
key has been lost or b) prior to
programming a new radio key to
replace another.
Radio Codes are automatically deleted
when the user code type is changed to
keypad code or reader code.
EXAMPLE: To delete Radio Code 56.
In Installer Program Mode: Press
KPX+
Press P256E 0E
NaVIGaTOr
Press P256E
P201E – P256E
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
No Radio Codes, all code are keypad
codes.
notEs
• User Code 1 (Master Code) is always
a Keypad Code.
• Radio Codes can be deleted by
keypad in the case of a lost Radio Key.
• Radio Keys are assigned to User
Codes, so that Open/Close reports are
identified by user number when the
control panel is base station monitored.
(If Open/Close reports are enabled)
• Enable a User Code as a Radio Code
in Extra Options - turn on 5E.
rELAtED oPtions
P101E–P116E Programming Radio
Devices.
User Code
Option
No.
Radio
Code?
1
(Master)
P201E
Keypad Only
2
P202E
3
P203E
4
P204E
5
P205E
6
P206E
7
P207E
8
P208E
9
P209E
10
P210E
11
P211E
12
P212E
13
P213E
14
P214E
15
P215E
16
P216E
17
P217E
18
P218E
19
P219E
20
P220E
21
P221E
22
P222E
23
P223E
24
P224E
25
P225E
26
P226E
27
P227E
28
P228E
29
P229E
30
P230E
31
P231E
32
P232E
33
P233E
34
P234E
35
P235E
36
P236E
37
P237E
38
P238E
39
P239E
40
P240E
41
P241E
42
P242E
43
P243E
44
P244E
45
P245E
46
P246E
47
P247E
48
P248E
49
P249E
50
P250E
51
P251E
52
P252E
53
P253E
54
P254E
55
P255E
56
P256E
EXTRA OPTIONS MODE
To enable a User Code as a Radio Code
go to EXTRA OPTIONS MODE and enable
option 5E for that code. See steps 1 to 4
in Programming Sequence.
KPX+
Press EXCLUDE E to enter and
exit Extra Options mode.
NaVIGaTOr
Press Extra Code Options to
enter Extra Options mode. Press
to
exit
USER CODE OPTIONS TABLE
See page 24 or 87 for the expanded table.
79
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
Summary of Contents for D16XCEL
Page 96: ......