Option No.
Description
Default
P199E
1E
Send Address
OFF
2E
Send Time Stamp
OFF
3E
Send Alarms
OFF
4E
Send Warnings
OFF
5E
Send Access Events
OFF
6E
Zone Seal State
OFF
7E
Send Test ASCII data
OFF
8E
[not used]
OFF
P199E
sEriAL oUtPUt oPtions
ProgrAm moDE LEVEL
Installer
FACtory DEFAULt
Options 1E-7E OFF - Serial data options
disabled.
notEs
The RS232 Serial data is output at 9600
baud, 8 data bits, no parity, 1 stop bit
Toggle the current setting for the ENABLING or DISABLING of USER Codes as set by the
D8x and D16x V5.6 and later have the option for two way serial data communications via
the onboard RS232 SERIAL port. Alarm and system messages can be sent and keypad/
status request data can be received. This allows high level interfacing with various external
devices/controllers/dataloggers and other.
Messages are in ASCII format. Due to space constraints, the full protocol is not printed in
this manual but is available on request.
KPX+
P199E xE to select one option as required
NAVIGATOR
P199E > select one option as required
SMS*
P[MasterCode]E P[InstallerCode]E P199E xE
Or use
NessXCEL
app
1E ON: Send Address. The address is the last digit of Acc No.2 (P73E).
2E ON: Send Time Stamp.
3E ON: Send Alarms.
4E ON: Send Warnings.
5E ON: Send Access Events.
6E ON: Send Zone Seal State. (D8x/D16x V6 and later.)
7E ON: Send test ASCII string. Sends test data periodically, used for testing the serial port
(D8x/D16x V6 and later.)
* SMS programming shows the full SMS string to send. KPX+ and
NAVIGATOR programming assumes the panel is already in program mode.
80
NESS D8XCEL / D16XCEL CONTROL PANEL – INSTALLATION MANUAL REV 1.1
P r o g r A m m i n g